SDCXS100 Calorific Value and Halogen Analyzer
The SDCXS100 Calorific Value and Halogen Analyzer is an integrated analytical system designed for the determination of calorific value, fluorine, chlorine, bromine and sulfur in solid and liquid combustible materials. It combines automatic bomb calorimetry, closed-system oxygen bomb combustion and ion chromatography in a fully automated workflow. The system is suitable for solid waste, hazardous waste, coal, coke, petroleum products, cement black meal and biomass fuels. From oxygen filling and combustion to bomb washing, absorption-solution preparation, dilution, storage and ion chromatographic analysis, the entire process is automated to improve laboratory efficiency, result consistency and operational safety.
PFAS Application
The SDCXS100 can support preliminary PFAS screening by determining total fluorine in combustible solid and liquid samples through oxygen bomb combustion followed by ion chromatography. Elevated fluorine results can be used to identify samples that may require further targeted PFAS investigation. As the system measures total fluorine rather than individual PFAS compounds, positive screening results should be confirmed using compound-specific techniques such as LC–MS/MS.
Key Features
Integrated Calorific Value and Halogen Analysis
The SDCXS100 integrates calorific value measurement with fluorine, chlorine, bromine and sulfur determination in a single system. Automated docking between the calorimeter and halogen-sulfur analysis module streamlines the complete analytical workflow and reduces manual sample handling.
Fully Automated Oxygen Bomb Operation
The system automatically performs oxygen filling and discharging, pressure detection, combustion-water volume determination, water-temperature adjustment and oxygen bomb washing. This minimizes operator intervention and improves testing consistency.
Automated Ion Chromatography Workflow
After combustion, the system automatically absorbs soluble combustion products and completes absorbing-solution collection, constant-volume preparation, storage, dilution and ion chromatographic analysis. Ion chromatography provides effective separation of different ionic species, reducing mutual interference while delivering low detection limits and reliable repeatability.
Rapid Analysis with High Throughput
Calorific value analysis is completed in less than 7.5 minutes, while the complete halogen and sulfur workflow takes less than 35 minutes, including washing, constant-volume preparation, dilution, storage and analysis. A 30-position autosampler automatically stores collected solutions, allowing calorific value testing to continue without being limited by the ion chromatography analysis cycle.
Stable and Precise Temperature Control
Automatic bucket-water temperature adjustment maintains closely controlled test conditions for each sample. Dual thermoelectric cooling and heating provides precise jacket-temperature control, improving environmental adaptability, long-term stability and measurement consistency. The specified calorific value RSD is ≤0.10%, with heat-capacity stability of ≤0.20% over three months.
Halogen-Resistant Oxygen Bomb
The specially designed halogen-resistant oxygen bomb improves resistance to corrosive combustion products generated by samples with high halogen concentrations. It is particularly suitable for demanding applications involving solid waste, hazardous waste and other complex combustible materials.
Adaptable to Difficult Samples
Dedicated solutions are available for samples with high volatility, high calorific value or high metal-salt content. Customized combustion bags with stable calorific characteristics facilitate the analysis of volatile or low-calorific-value samples while helping protect oxygen bombs, crucibles and related accessories.
Simplified Operation and Maintenance
The all-in-one calorimeter incorporates a large touchscreen and requires no external cooling-water tank. Self-diagnostic functions, a clearly structured system layout and a dedicated oxygen-bomb opening tool simplify routine operation and maintenance.
Flexible Data Management
The system uses an open database architecture and can be connected to a Laboratory Information Management System (LIMS) for automatic collection, transfer and management of analytical data.
Applicable International Standards and Methods
| Standard | Standard Title | Applicable Samples |
| EN 14582 | Characterization of Waste — Halogen and Sulfur Content — Oxygen Combustion in Closed Systems and Determination Methods | Solid, pasty and liquid waste samples |
Specifications
Calorific Value Analysis
Sample Mass: 0.05–1 g
Analysis Time: <7.5 min
Temperature Resolution: 0.0001°C
Repeatability (RSD): ≤0.10%
Heat Capacity Stability: ≤0.20% within three months
Halogen and Sulfur Analysis
Analytical Method: Ion chromatography
Analysis Time: <35 min, including washing, constant-volume preparation, dilution, storage and analysis
Detection Limits:
F: 20 mg/kg
Cl: 20 mg/kg
Br: 20 mg/kg
S: 20 mg/kg
Autosampler Capacity: 30 samples
Maximum Power: 0.75 kW
Power Supply: AC 220 V ±10%, 50/60 Hz
Standard Configuration
Calorimeter: Integrated touchscreen
Calorimeter Dimensions: 542 × 400 × 490 mm
Calorimeter Weight: 54 kg
Halogen Analysis Module: Supplied with computer
Halogen Module Dimensions: 492 × 430 × 780 mm
Halogen Module Weight: 50 kg
Application Notes
We are compiling our practical application experience into a growing collection of technical articles that will be published here regularly.
If you have an immediate analytical challenge before then—whether in mining, energy, advanced materials, or PFAS analysis—contact the Sundy Technology Application Laboratory. We provide customized method development, application optimization, and technical support to help you achieve reliable analytical results.
Schematic Diagram

On-site Photos



Videos
Our video library is currently under development, featuring product operation tutorials, application demonstrations, and technical explainers. Stay tuned for regular updates.
Customer Testimonials
We have provided a complete set of Sundy testing solutions, including bomb calorimeter, sulfur analyzer, and thermogravimetric analyzer, to the fuel analysis laboratory of Kavçim Cement, a leading integrated cement plant on Turkey’s Black Sea coast. Sundy’s standardized instrument performance bring outstanding practical value to end users. The upgraded solution significantly simplifies daily operations, lowers manual intervention and maintenance costs, and unifies data consistency for routine fuel analysis.We are very satisfied with Sundy’s product quality and technical support, and will continue to promote and recommend Sundy analytical instruments for more industrial laboratory projects in Turkey.
After more than 10 years of continuous cooperation and market verification, we confirm that Sundy’s products, especially its automatic calorimeters and elemental analyzers, have high precise temperature control, accurate testing results, and ultra-low failure rate. All products are fully compliant with international ISO and ASTM standard, completely meeting the testing demands of coal laboratories, power plants, industrial enterprises, universities and scientific research institutions.We highly recognize Hunan Sundy Science and Technology’s strong production capacity, standardized quality management system, professional technical support team and excellent business credibility. In all our cooperation cases, Sundy has always demonstrated professionalism, reliability and a customer-oriented service attitude.
FAQs
Downloads
Have Questions? Contact Us Directly
Share your application details and our team will recommend a suitable configuration.

Get professional advice for your application and project.
Request a detailed quotation quickly and easily.

Find the best solution for your specific application.
Inquire about parts, availability and delivery.