SDXRF1000t EDXRF Spectrometer

The SDXRF1000t EDXRF Spectrometer is a benchtop energy dispersive X-ray fluorescence analyzer for fast, non-destructive elemental analysis of coal, ores, metals and geological materials. It quantifies major, minor and trace elements from sodium (Na) to uranium (U), from ppm to 99.99%, in powders, solids and liquids — with minimal sample preparation and all elements in a single short run.

A 50 W X-ray tube, a high-resolution SDD detector and proprietary SES digital pulse processing pair with software-switched collimators and multi-filter optics for stable excitation and clean spectra. An optional vacuum path improves light-element results for Mg, Al, Si, P and S, while electric cooling requires no consumables. Proprietary software combines empirical and theoretical-alpha corrections, curve fitting, user-built calibrations and exportable reports.

From ore grading and coal ash characterization to alloy verification and at-line process control, the SDXRF1000t brings laboratory-grade data to routine QC in a compact, multi-shielded system.

Key Features

Fast Analysis, High Precision, Superior Efficiency
Equipped with proprietary analysis software, the instrument can simultaneously and accurately analyze dozens of elements from sodium (Na) to uranium (U) within 100 seconds.

Elegant and Robust Exterior Design with Multiple Safety Protection Modes
The instrument features a sleek, aesthetically pleasing appearance, durable construction, and multi-layered safety protection mechanisms.
 

Collimator + Multi-Combination Filter Optical System
Utilizing a “collimator + multi-combination filter” collimation and filtering system with automatic software-driven switching, the instrument accommodates a wide range of testing applications.
 

Self-Developed SES Signal Processing System (Digital Multi-Channel Analyzer)
The proprietary SES signal processing system effectively improves the peak-to-background ratio, delivering more accurate measurements.

Multi-Dimensional Heat Dissipation System
An optimized integrated thermal design significantly enhances overall heat dissipation performance, ensuring the safe operation of the X-ray source.

Radiation Safety System
Multiple layers of anti-radiation leakage design provide the highest level of radiation protection among comparable products.

Optional Vacuum System
An optional vacuum pumping system optimizes the testing environment, improves the analytical accuracy of light elements such as magnesium (Mg), aluminum (Al), silicon (Si), phosphorus (P), and sulfur (S), and greatly expands the instrument’s analytical capabilities.

Proprietary Core Temperature Monitoring Technology
An exclusive core temperature monitoring system ensures safe and reliable operation of the X-ray source, effectively extends its service life, and reduces operating costs.

Core Components — Fully Imported
① Imported U.S.-made SDD detector: resolution as low as Mn Kα 125 ± 5 eV; excellent energy linearity and energy resolution; high peak-to-background ratio.
② Imported Oxford tube core: maximum power 50 W, tube voltage 5–50 kV, tube current 0–1000 µA; long-life X-ray tube.
③ Imported Spellman high-voltage power supply: maximum power 50 W, voltage 0–50 kV, current 0–1000 µA; 8-hour stability ≤ 0.05%.
④ Imported signal processor: suitable for high resolution and high count rates; auto-adjusting amplification factor; maximum number of channels: 4096.

Proprietary Analysis Software
Integrates multiple analytical methods — including empirical coefficient method, theoretical alpha coefficient method, linear fitting, quadratic curve fitting, intensity correction, and concentration correction — to comprehensively ensure the accuracy of test data.

Applicable International Standards and Methods

 

StandardStandard TitleApplicable Samples
GB/T 37673-2019Determination of silicon, aluminum, iron, calcium, magnesium, sodium, potassium, phosphorus, titanium, manganese, strontium and barium in coal ash — X-ray fluorescence spectrometric methodCoal

Specifications

Element range: sodium (Na) to uranium (U)

Concentration range: from ppm – 99.99% (different elements, different analysis range)

Sample types: powder, liquid, solid

Optimum resolution: MnKα 125±5eV

X-ray tube: 50W, 0-50KV, 0-1000μA

Analysis time: 100–200s (adjustable according to actual sample conditions)

Cooling method: electric refrigeration, no consumables required

Sample chamber size: 400mm×340mm×80mm

Appearance size: 700mm×510mm×336mm

Power supply: AC 220V±10%, 50Hz±1Hz

Working environment: 15–35℃, RH≤80% (no condensation)

Application Notes

We are compiling our practical application experience into a growing collection of technical articles that will be published here regularly.

If you have an immediate analytical challenge before then—whether in mining, energy, advanced materials, or PFAS analysis—contact the Sundy Technology Application Laboratory. We provide customized method development, application optimization, and technical support to help you achieve reliable analytical results.

Intuitive Software Ensures Simple Operation
On-site Photos
Videos

Our video library is currently under development, featuring product operation tutorials, application demonstrations, and technical explainers. Stay tuned for regular updates.

Customer Testimonials
We have provided a complete set of Sundy testing solutions, including bomb calorimeter, sulfur analyzer, and thermogravimetric analyzer, to the fuel analysis laboratory of Kavçim Cement, a leading integrated cement plant on Turkey’s Black Sea coast. Sundy’s standardized instrument performance bring outstanding practical value to end users. The upgraded solution significantly simplifies daily operations, lowers manual intervention and maintenance costs, and unifies data consistency for routine fuel analysis.We are very satisfied with Sundy’s product quality and technical support, and will continue to promote and recommend Sundy analytical instruments for more industrial laboratory projects in Turkey.
Dr. Karahan, POTANTEK
After more than 10 years of continuous cooperation and market verification, we confirm that Sundy’s products, especially its automatic calorimeters and elemental analyzers, have high precise temperature control, accurate testing results, and ultra-low failure rate. All products are fully compliant with international ISO and ASTM standard, completely meeting the testing demands of coal laboratories, power plants, industrial enterprises, universities and scientific research institutions.We highly recognize Hunan Sundy Science and Technology’s strong production capacity, standardized quality management system, professional technical support team and excellent business credibility. In all our cooperation cases, Sundy has always demonstrated professionalism, reliability and a customer-oriented service attitude.
Dr. Kim, YEONJIN
FAQs

The SDXRF1000t is a benchtop energy dispersive X-ray fluorescence (EDXRF) spectrometer for fast qualitative and quantitative elemental analysis of coal, coal ash, ores, alloys, cement, soil, refractories and geological materials.

An X-ray tube excites atoms in the sample, which emit element-specific characteristic X-rays. An SDD detector converts these into electrical pulses; the software identifies elements from peak energy and calculates concentrations from peak intensity.

Elements from sodium (Na) to uranium (U), with dozens of elements measured simultaneously in a single run.

From ppm levels up to 99.99%. The usable range depends on the element and the sample matrix.

Powders, solids and liquids. Powders are normally pressed into pellets; liquids are held in sample cups with test film.

No. No chemical digestion is required. A manual pellet press, sample cups and test film are supplied with the instrument.

Yes. EDXRF is a physical, non-destructive method, so the sample can be retained for re-testing or archival.

Measurement time is adjustable from 1 to 120 seconds, depending on the sample and the required precision.

An imported SDD detector with an ultra-thin entrance window, Mn Kα resolution of 125 ± 5 eV, a 4096-channel digital multi-channel analyzer and a count rate of up to 1000 kcps.

A long-life rhodium-target X-ray tube rated at 50 W, 5–50 kV and 0–1000 µA, driven by a Spellman high-voltage generator (0–50 kV, 0–1000 µA) with 8-hour stability ≤ 0.05%.

Initialization fixes the energy scale so that peaks of the same element always appear at the same channel. Copper is the default initialization element.

The sample chamber is 400 × 340 × 80 mm. The instrument measures 705 × 475 × 320 mm and weighs 56 kg.

AC 220 V ± 5 V, 50 Hz, approximately 300 W excluding the vacuum pump. Ambient temperature 15–35 °C, relative humidity ≤ 80% (non-condensing). A regulated or UPS supply is recommended, and 18–26 °C is advised for long-term stability.

No. The detector is electrically cooled and requires no liquid nitrogen or cooling consumables.

Evacuating the sample chamber reduces absorption of low-energy X-rays and improves the accuracy of light elements such as Mg, Al, Si, P and S.

A collimator and multi-combination filter system is switched automatically by the software to match the elements and sample type being measured.

Sundy’s proprietary digital multi-channel signal processing system, designed to improve the peak-to-background ratio and measurement accuracy.

Empirical coefficient, theoretical alpha coefficient, linear and quadratic fitting, intensity correction and content correction, with EC and FP working curve types.

Yes. Working curves can be created, imported, exported, renamed and deleted. The software also supports element editing, influencing-element correction, and spectrum processing for escape peaks, sum peaks and background subtraction.

Yes. Qualitative analysis offers automatic and manual peak identification, with adjustable FWHM, sensitivity, peak-to-valley and area-ratio thresholds.

Reports can be saved or printed as Excel or PDF, with optional encryption. History records can be queried by name, date or working curve and exported to Excel in full or by template.

Yes. The interface switches between Chinese and English. User management supports administrator, technician and operator permission levels, plus password protection, backup and restore, and USB dongle licensing.

Switch on the main supply, then the instrument, printer and computer. Allow a 15-minute warm-up, run initialization with the copper reference sample, then begin measurement.

Multiple radiation leakage protection designs, a radiation indicator lamp, high-voltage and lid interlocks, core temperature monitoring of the X-ray source, and an integrated heat dissipation design.

Keep the instrument dry, clean and dust-free in a stable, vibration-free environment; use a regulated power supply; wipe with a soft cloth or alcohol swab only; never use corrosive cleaners or open the housing. Handle samples with tweezers to protect the measurement window film, keep the vacuum pump oil at about 3/4 of the sight glass between the minimum and maximum marks, and cover the instrument when idle.

The main unit, PC and monitor, printer, vacuum pump, manual pellet press, sample cups, test film, coal ash reference material, copper calibration sample, USB dongle, power and USB cables, and the user manual.

Related Products

SDTGA6000A Thermal Analyzer

SDS720 Coulomb Sulfur Analyzer

 SDDH315t Nitrogen-Purged Drying Oven

Have Questions? Contact Us Directly

Share your application details and our team will recommend a suitable configuration.

Technical Consultation

Get professional advice for your application and project.

Quotation Request

Request a detailed quotation quickly and easily.

Application Support

Find the best solution for your specific application.

Spare Parts Inquiry

Inquire about parts, availability and delivery.